Skip the Scrub, Not the Clean

(by Karen Daw, MBA, CECM, CDIPC)

 

Part 2: Less Time in Sterilization. More Time Chairside.

In Part 1, Clean Before You Steam, we looked at why cleaning comes first—and why rushing it can create more work later.

Read Part 1: Clean Before You Steam

Now let’s look at another part of the equation: How much employee time and handling does cleaning require?

Because the time a machine runs and the time an employee spends are not the same thing.

Count the Hands-On Time

When comparing cleaning methods, don’t look only at how long the equipment runs. Look at how much employee time the entire process requires.

With an ultrasonic cleaner, the team may prepare the solution, load the instruments, start the cycle, remove them, rinse them, inspect them and repeat the process for the next load.

An automated instrument washer performs more of those steps inside the machine while the assistant returns to patient care.

If everything does not fit, another cycle begins. Instead of asking only, “How long does the machine run?” ask:

“How much hands-on employee time does the complete process require?”

The value is not simply speed. It is less hands-on employee time.

Reduce the Touchpoints

There is another reason to pay attention to handling.

Until instruments have been appropriately decontaminated, they should be treated as contaminated. Loading, unloading, rinsing, sorting and other handling create opportunities for a sharp edge or point to puncture a glove or skin.

The CDC recommends automated cleaning equipment, including ultrasonic cleaners and washer-disinfectors, to improve cleaning effectiveness and decrease worker exposure to blood.

That makes reducing handling both an efficiency and an exposure-prevention conversation.

Automated washer workflows can replace ultrasonic cleaning for many instruments. However, some devices or challenging soils may still require ultrasonic pretreatment according to the manufacturer’s instructions.

For routine cassette processing, automation can significantly reduce the repeated handling and employee involvement associated with ultrasonic workflows. If several ultrasonic cycles are required to process the day’s cassettes, employees may repeat the entire cleaning process several times.

Automation Adds Consistency

There is another benefit: repeatability.

Manual processes rely on people completing multiple steps correctly every time—even when patients are waiting and someone needs help chairside.

Automated equipment moves more of the cleaning process into programmed, controlled cycles.

Instead of asking whether someone remembered every step at exactly the right time, the practice has a defined process that can be repeated consistently.

When Thermal Disinfection Changes the OSHA Conversation

OSHA defines an exposure incident as specific contact with blood or other potentially infectious material (OPIM). Saliva in dental procedures is considered OPIM.

If an instrument has successfully completed a validated thermal-disinfection process and no longer presents a bloodborne-pathogen hazard, a later puncture is still an injury that should be reported and assessed. However, it may not meet OSHA’s definition of a bloodborne-pathogen exposure.

The practice should confirm that the intended cycle was completed successfully and that there was no process failure or visible soil.

Match the Problem to the Solution

Before comparing equipment, follow the instruments through a busy day.

Where does the process slow down?

No single option is automatically best for every practice.

Choose the workflow first. Then choose the equipment that removes the practice’s actual bottleneck.

Questions Leaders Should Ask

  • How many times are ultrasonic cleaners used on a busy day?
  • How much hands-on employee time does each cycle require?
  • How many times are contaminated instruments handled?
  • Are cassettes waiting for space in the equipment?
  • Is rinsing or drying adding another hands-on step?
  • Are team members following the manufacturers’ instructions for use (IFUs) for the instruments, cassettes, ultrasonic unit, cleaning solution and enzymatic solution?
  • Could automation eliminate some of those steps or touchpoints?
  • Which cleaning process returns the assistant chairside quickly and with the least hands-on work?

Do not evaluate equipment only by how long the machine runs. Evaluate how much employee work remains when the machine finishes.

The goal is not to make dental assistants faster in sterilization. It is to build a process that requires less of their time there.

 

> “Less time in sterilization. More time chairside. That’s the goal.”

 

Written by Karen Daw, MBA, CECM, CDIPC
Originally published HERE